BW Defender2
User Manual
16
Alarms
Table 6 describes the detector alarms and shows how the
display looks for each alarm.
Table 7 describes the computed gas exposure for
the Time Weight Average for TWA (LTEL).
LTEL (Long Term Exposure Limit) = TWA
During an alarm condition, the detector activates the
backlight and the display shows the current ambient gas
reading. Gas alarms are latching.
The High Alarm overrides a TWA alarm and a TWA Alarm
overrides a Low Alarm.
Table 6. Alarms
Alarms Display Alarms Display
Instant Low Alarm:
Slow modulating tone
and flash.
ALARM and target
gas bar flash.
Instant High Alarm:
Fast modulating tone
and flash.
ALARM and target
gas bar flash.
Latching Alarm User Option: If the Latched Alarm function is turned ON, the audible and visual alarms continue to sound and
flash until the Low or High Alarm condition is acknowledged. Press to deactivate the audible and visual alarms when the current
ambient gas reading falls below the low alarm level. The alarms cannot be deactivated if an alarm condition is still present.
A TWA alarm condition will not reset.