Black & Decker MULTI-GAS DETECTORS Manual do Utilizador Página 48

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 47
BW Defender2
Replacing a Sensor or Sensor Filter
37
Table 12 and Figure 5 illustrate how to replace a sensor or
sensor filter. If the detector is on, shut down the detector. Use
a Phillips head screwdriver to loosen and tighten any screws.
Do not use excessive force when removing or inserting the
sensor, or the sensor may be damaged. Gently rocking the
sensor back and forth may help free a tightly held sensor.
Insert new sensor in the compartment.
Note: 2-gas Detector is equipped with a dummy twin-tox
sensor.
Table 12. Replacing a Sensor or Sensor Filter
Item Description
A Cover Screws
B Sensor Cover
C Sensor replaceable screens
D Sensors (LEL and O
2
)
E Sensor – Twin Tox (H
2
S, CO)
Figure 5. Replacing a Sensor or Sensor Filter
A
B
C
D
E
Vista de página 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 70 71

Comentários a estes Manuais

Sem comentários